Downgrade - setting reduced charging current

Using DIP switches 4 and 5 on bank S2, the reduced charging current, which is present when the switching contact at the downgrade input is controlled, can be set. The charging current is reduced as a percentage depending on the maximum set charging current.

Configure the setting as desired.

Configurable functions:

Bank

DIP switch

Max. charging current
per phase

Reduced
charging current at 16 A

Reduced
charging power

5

4

as a %

At 16 A

1ph at 3.7 kW

3ph at 11 kW

2

OFF

OFF

0 %

0 A

0 kW

0 kW

ON

OFF

25 %

6 A

1.4 kW

4.1 kW

OFF

ON

50 %

8 A

1.85 kW

5.5 kW

ON

ON

75 %

12 A

2.8 kW

8.25 kW

 

INFO

Info

Too low a charging current as a result of an incorrect configuration

Upon delivery, the wallbox is set to the percentages shown in the table for the maximum charging current per phase. A charging current set to more than 0 A or less than 6 A is always set to 6 A.

These values can only be adjusted using the ENECTOR Config Tool.

You will find the ENECTOR Config Tool and instructions for how to use it in the download area > ENECTOR by going to Update.