Example of DIP setting depending on application
INFO
Bank 2 (S2): If the values for your installation deviate from this example, e.g. for a house connection fuse of only 50 A, this must be adapted using the DIP switches.
Settings for bank 2 (S2) in this example:
- The maximum charging current per phase is set to 16 A (bank 2 / DIP 1-3).
- The maximum current for the house connection is set to 63 A (bank 2 / DIP 6-8).
ENECTOR without energy meter
Bank | DIP switch | |||||||
---|---|---|---|---|---|---|---|---|
8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | |
2 | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF |
1 | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF |
ENECTOR with KOSTAL Smart Energy Meter and convenience functions
Bank | DIP switch | |||||||
---|---|---|---|---|---|---|---|---|
8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | |
2 | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF |
1 | OFF | ON | ON | ON | ON | OFF | OFF | OFF |
INFO
In order for the wallbox to be set up with the convenience functions in the KOSTAL Smart Energy Meter (KSEM), this function must first be activated via an activation code for the wallbox in the KSEM.
The activation code can be purchased from the KOSTAL Solar online shop.
To access the shop, go to: shop.kostal-solar-electric.com.
ENECTOR with KOSTAL Smart Energy Meter for blackout protection (house connection monitoring)
Bank | DIP switch | |||||||
---|---|---|---|---|---|---|---|---|
8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | |
2 | OFF | OFF | OFF | OFF | OFF | OFF | OFF | OFF |
1 | OFF | OFF | ON | OFF | ON | OFF | OFF | OFF |