Setting maximum charging current per phase
The max. charging current per phase for charging an electric vehicle can be set between 6-16 A. This must be compliant with the fuse protection (line circuit breaker / residual current device) of the wallbox.
Configure the setting as desired.
Configurable functions:
Bank | DIP switch | Charging current per phase (A) | Charging power (kW) | |||
---|---|---|---|---|---|---|
3 | 2 | 1 | Connection | |||
1-phase | 3-phase | |||||
2 | OFF | OFF | OFF | 16 | 3.7 | 11 |
ON | OFF | OFF | 13 | 3.0 | 9 | |
ON | OFF | ON | 10 | 2.3 | 6.9 | |
ON | ON | OFF | 6 | 1.4 | 4.1 |