Installing the modules

The storage system does not need any additional fastening elements between the individual battery modules. Instead, fasteners are used to secure the system to the wall and thereby prevent it from tipping over.

A fastener can be attached to each battery module and the Battery Management System (BMS).

We would recommend securing every third battery module with a fastener. In each configuration, the Battery Management System (BMS) is separately fastened to the wall with a fastener.

Holes will have to be drilled in the wall to mount the fasteners and stably fix the system.

Refer to the table below to see which battery module requires a fastener. The quantity and position depend on the number of modules.

Battery modules per tower

Number of fasteners

Position of fastening points

BMS

1

BMS always

2

None

None

3

1

Battery module 3

4

1

Battery module 4

5

2

Battery module 3/5

6

2

Battery module 3/6

7

2

Battery module 3/7

8

3

On battery module 3/6/8

9

3

On battery module 3/6/9