DC connection for battery/inverter

Mounting plug on DC cable

Use a cable cross-section of at least 6 mm² (10 AWG) as the DC battery cable. The cable cross-section must be selected taking into account the system size and also the requirements of the inverter.

INFO

Info

Using a crimping tool

If a cable cross-section of 10 mm² is used, a hydraulic crimping tools should be used.

 

At the battery end, use the DC plugs for the battery provided.

At the inverter end, use the DC plugs that were provided for the inverter and fit these.

Connecting DC cables to the battery and inverter

Plug the DC cables into the battery until they engage. Then attach the DC cables to the inverter until they engage.