Info menu
On the Info page, the user can view events pending in the inverter and the inverter's installed version (e.g. software, MC, IOC, hardware). This information can also be viewed without logging in to the Webserver.
Device information – Devices
Shows information about the versions installed on the inverter.
Parameter | Explanation |
---|---|
Name | Name of inverter Can be changed by going to Settings > Basic settings. |
Serial number | Inverter serial number |
Guideline | The configured country setting for the inverter |
Firmware version | Inverter safety firmware version. Contains the safety, open and shutdown functions required for appliance safety and grid service functions. |
Master CB version | Firmware version master communication board (MCB Master Control Board) |
Slave CB version | Firmware version slave communication board (SCB Slave Control Board) |
Communication board version | Firmware version of the communication service board (CSB Communication Service Board) |
AFCI version | Arc detection version |
Device information – Network
Provides information about the assigned network settings.
LAN settings
Parameter | Explanation |
---|---|
IP mode | The DHCP option is activated by default. This means that the inverter obtains its IP address from a DHCP server. Select static IP to assign the IP address yourself in IP address. It goes without saying that this address must be available in your system. |
IP address | Enter IP address of inverter. If the inverter is not allocated an IP address automatically through a DHCP server, the inverter can be configured manually. The data necessary for configuration, such as IP, subnet mask, router and DNS addresses, can be found on your router/gateway. |
Subnet mask | Enter the subnet mask e.g. 255.255.255.0 |
Router/gateway | Enter the IP address of the router/gateway |
Auto DNS | The Auto DNS option is activated by default. This means that inverters can also be addressed using a name instead of an IP address. For this purpose, the IP addresses of the DNS servers must be entered. |
DNS server 1 | Enter the IP address of the DNS server (Domain Name System) |
DNS server 2 | Enter the IP address of the backup DNS server (Domain Name System) |
Last time of communication | Shows when communication with the inverter last took place. |
Launch network diagnostics | Starts network diagnostics. The result is subsequently shown. |
Communication status | Shows the status of communication with the grid. |
Solar portal parameters | Explanation |
---|---|
Last connection to the solar portal | Last transfer, shown in minutes or as a time |
Last communication status | Indicates whether the transfer was successful. |