KOSTAL Smart Energy Meter – Events
The events / messages listed here may appear on the KOSTAL Smart Energy Meter.
KOSTAL Smart Energy Meter events – device settings
Event code | Type of event | Description / possible cause / action |
|---|---|---|
100 | The backup could not be imported. Please repeat the process. | The backup import could not be carried out. Please first check that you have selected the locally stored backup file and entered the correct password. If the error can be ruled out based on the backup file and password, a new backup file of the original device must be created where possible. Ensure that the file extension and file type are not altered. The import process can now be carried out again. |
101 | The backup could not be created. Please repeat the process | The backup could not be created. Please repeat the process. |
102 | The backup could not be created. Please repeat the process. | An error occurred whilst exporting the backup. The backup could not be created. Please check the selected settings and try again after restarting the device. If the error persists, please create a system log and contact the manufacturer’s support team. |
103 | The backup could not be restored. Please check the backup file you are using and repeat the process. | An error occurred whilst importing the backup file. Please check the file extension and file size of the backup file. If possible, create the backup file again and repeat the process. If the error persists, please generate a system log and contact the manufacturer’s support team. |
104 | The backup could not be restored. Please check the backup file you are using and repeat the process. | The operation could not be carried out because the backup file is too large. Please check the file extension and file size of the backup file. If possible, create the backup file again and repeat the process. If the error persists, please generate a system log and contact the manufacturer’s support team. |
105 | The backup could not be restored. Please check the backup file you are using and repeat the process. | The operation could not be carried out because the backup contains an incorrect software version. Please check and update the device with the outdated software, then create a new backup. Now repeat the restoration process. |
106 | The backup could not be restored. Please check the backup file and password used. Then repeat the process. | The password entered or the backup file provided is not valid. Please check the file used and the corresponding password. If you do not have this information, please create a new backup file with a password and repeat the process. |
107 | The firmware update could not be installed. Please check the update you are using and repeat the process. | The firmware upgrade could not be carried out. Please check that the firmware file used is the correct version. Alternatively, download the firmware again from the manufacturer’s website and repeat the process. |
108 | The system is in safe mode. Please restore a valid backup or reset the device to its factory settings. | The system is in a secure state. If available, please restore a valid backup file. If this is not possible, please reset the device to its factory settings. |
109 | Time synchronisation could not be completed successfully. Please check the NTP server, the time zone and your internet connection in the device settings. | Synchronisation with the time server (NTP server) has failed. Please check your internet connection and server settings, then reload the page. |
110 | The firmware could not be installed; an internal error has occurred. | The fault ‘The firmware could not be installed; an internal error has occurred’ cannot be resolved by the user . Please generate a system log and contact the manufacturer’s support team. |
111 | The firmware is not compatible with this device. | The firmware being used is not compatible with this device type. Please generate a system log and contact the manufacturer’s support team. |
112 | The firmware is not compatible with this product. | The firmware is not compatible with your product. Please check the product name under ‘Device Settings’ > ‘System Information’ and compare it with the firmware being used. If the product specifications differ, you will need firmware that is compatible with the device. If the error persists, please generate a system log and contact the manufacturer’s support team. |
113 | The firmware signature is incorrect. | The firmware could not be successfully installed. Please download the firmware again from the download section and try the update again. If the error persists, please generate the system logs and contact the manufacturer’s support team. |
114 | The signature could not be verified. | The certificate used in the firmware is not compatible with your device. Please check the product name and description of the firmware being used under Device Settings – System Information. If the product specifications differ, you will need firmware that is compatible with your device. If the error persists, please generate the system logs and contact the manufacturer’s support team. |
115 | The requested firmware has since been withdrawn or replaced by a newer version. Please try again. | Between the last data retrieval from the update server and the current update attempt, the most recently retrieved update version has been withdrawn or replaced by a newer version. Please try again. If the error persists, please generate the system logs and contact the manufacturer’s support team. |
Events: KOSTAL Smart Energy Meter – File System Check
Event code | Type of event | Description / Possible cause / Action |
|---|---|---|
150 | The system has detected a fault in the file system. | The malfunction – an application error occurred during the file system check – cannot be resolved automatically. Please generate a system log and contact the manufacturer’s support team. |
151 | The system has detected a problem with the file system. | The fault ‘Irreparable error detected in the file system ’ cannot be rectified automatically. Please generate a system log and contact the manufacturer’s support team. |
KOSTAL Smart Energy Meter events – Tariffs
Event code | Type of event | Description / possible cause / action |
|---|---|---|
450 | The database could not be updated. Please repeat the process | The fault with error code 450: ‘Failed to write to the database’ cannot be resolved by the user. Please contact the manufacturer’s support team. |
KOSTAL Smart Energy Meter events – Flash memory
Event code | Type of event | Description / possible cause / action |
|---|---|---|
500 | To prevent data loss, the device is in safe mode and no further data is being written. | The fault caused by the end of the flash memory’s service life cannot be rectified by the user. Please contact the manufacturer’s support team. |
Events KOSTAL Smart Energy Meter – Smart Grid
Event code | Type of event | Description / possible cause / action |
|---|---|---|
501 | An invalid incoming connection attempt to the device has been detected. | Check the EEBus settings on the EEBus remote station. An attempt is being made to establish a connection via EEBus with the KOSTAL Smart Energy Meter. On the KOSTAL Smart Energy Meter, however, the connection has been disconnected. |
Events KOSTAL Smart Energy Meter – EEBus
Event code | Type of event | Description / possible cause / action |
|---|---|---|
550 | The system was unable to initialise the EEBus component. Connections to other EEBus devices cannot be established. | The EEBus component could not be initialised successfully. Please check the network connections and restart the device if necessary. |
551 | An invalid incoming connection request to the device has been detected. | A connection attempt to the device was rejected because the connection parameters are invalid. Please check the connection parameters (e.g. PIN, certificate, SKI) and try again. If the error persists, please contact the manufacturer’s support team. |