PIKO MP plus - battery control

Install the KOSTAL Smart Energy Meter at the grid connection point within the domestic network, as shown in the illustrations.

INFO

Info

If battery management is enabled in the KOSTAL Smart Energy Meter, its installation position can no longer be set in the PIKO MP plus. It is essential that the KOSTAL Smart Energy Meter is installed at the grid connection point.

Establish and connect the RS485 communication cable between the inverter and the KOSTAL Smart Energy Meter RS485 (B).

Establish and connect the RS485 communication cable between the battery and the KOSTAL Smart Energy Meter RS485 (A).

Establish a LAN connection from the KOSTAL Smart Energy Meter, the battery and the inverter to the internet. Optionally, the LAN connection from the inverter or battery can also be connected directly to the KOSTAL Smart Energy Meter (switch function).

INFO

Info

For details, see the inverter's operating manual and the KOSTAL Smart Energy Meter's installation instructions.

In this configuration, the KOSTAL Smart Energy Meter acts as the master and sends data to the inverter and battery.

INFO

Info

Type and source of the hazard

If the battery is switched off manually for any reason, the following switch-on sequence must be observed:

  • Switch off the inverter
  • Switch on the battery
  • Switch on the inverter

The PIKO MP plus and the battery must be set up in the KOSTAL Smart Energy Meter.

To do this, carry out the following steps:

  1. Call up online interface of KOSTAL Smart Energy Meter Calling up user interface
  2. To use a battery with the PIKO MP plus, you must enable this function in the KOSTAL Smart Energy Meter. To do this, enable battery management under ‘Activation Code ’.
  3. INFO

    Info

    Enter an activation code, e.g. to connect a battery. This must first be purchased from the KOSTAL Solar Webshop.

  4. Next, the devices can be set up. To do this, go to the menu item ‘System settings’ > ‘Device manager’ (manage the inverters in use).
  5. Add an inverter using the ‘Add’ button.

INFO

Info

When selecting an inverter, the predefined default values are applied. These can be adjusted if necessary.

Parameters

Value

Series

Select PIKO MP plus.

Type

Select the appropriate type/power class of the inverter. This automatically sets the maximum AC output power of the inverter.

Serial interface

NOTE! The pre-assigned interfaces must first be deactivated. To do this, click on the relevant interface in the pop-up message.

Select the RS485 interface to which the PIKO MP plus is connected to the KOSTAL Smart Energy Meter.

Timeout

Accept the default value.

Maximum output power

This value must be set for every connected inverter. Selecting the type/inverter power class automatically sets the inverter’s maximum output power. The maximum output power is the maximum power that the inverter to be configured is technically capable of delivering.

Battery management

Enable battery support.

Battery serial interface

Specifies the RS485 interface on the KOSTAL Smart Energy Meter to which the battery’s communication cable is connected.

Battery type

Select the battery type, e.g. BYD HVM or BYD HVS.

Number of modules

Select the number of modules installed in the battery.

Max. SOC (State of Charge)

Set the maximum state of charge for the battery (default 100%).

Min. SOC (State of Charge)

Set the minimum state of charge for the battery. Please refer to the battery manufacturer’s specifications (default 5%).

Nominal battery charging/discharging power

This value is set automatically and does not need to be changed. It is calculated based on the battery type and the number of modules. However, it can be adjusted if the values do not match the battery specifications.

Open advanced settings

RS485 address

Enter the inverter’s RS485 address. This must be unique for each device and must not be duplicated.

  1. Press the Save button to adopt the settings.
  1. The PIKO MP plus and the battery have been set up in the KOSTAL Smart Energy Meter.