PIKO MP plus - battery control

Install the KOSTAL Smart Energy Meter at the grid connection point within the domestic network, as shown in the illustrations.
INFO

If battery management is enabled in the KOSTAL Smart Energy Meter, its installation position can no longer be set in the PIKO MP plus. It is essential that the KOSTAL Smart Energy Meter is installed at the grid connection point.
Establish and connect the RS485 communication cable between the inverter and the KOSTAL Smart Energy Meter RS485 (B).
Establish and connect the RS485 communication cable between the battery and the KOSTAL Smart Energy Meter RS485 (A).
Establish a LAN connection from the KOSTAL Smart Energy Meter, the battery and the inverter to the internet. Optionally, the LAN connection from the inverter or battery can also be connected directly to the KOSTAL Smart Energy Meter (switch function).
INFO

For details, see the inverter's operating manual and the KOSTAL Smart Energy Meter's installation instructions.
In this configuration, the KOSTAL Smart Energy Meter acts as the master and sends data to the inverter and battery.
- Please note the following installation sequence during set-up:
INFO

In the PIKO MP plus, the battery must be assigned to a DC input. This is done in the PIKO MP plus under the menu item Settings > Service > Inputs > DCx > Battery.
- Switching off the inverter by operating the DC switch
- Switch off the battery using the main switch
- Switch on the battery using the main switch
- Configure the inverter and the battery in the KOSTAL Smart Energy Meter
- Switching on the inverter by operating the DC switch
INFO

Type and source of the hazard
If the battery is switched off manually for any reason, the following switch-on sequence must be observed:
- Switch off the inverter
- Switch on the battery
- Switch on the inverter
The PIKO MP plus and the battery must be set up in the KOSTAL Smart Energy Meter.
To do this, carry out the following steps:
- Call up online interface of KOSTAL Smart Energy Meter Calling up user interface
- To use a battery with the PIKO MP plus, you must enable this function in the KOSTAL Smart Energy Meter. To do this, enable battery management under ‘Activation Code ’.
INFO

Enter an activation code, e.g. to connect a battery. This must first be purchased from the KOSTAL Solar Webshop.
- Next, the devices can be set up. To do this, go to the menu item ‘System settings’ > ‘Device manager’ (manage the inverters in use).
- Add an inverter using the ‘Add’ button.
INFO

When selecting an inverter, the predefined default values are applied. These can be adjusted if necessary.
Parameters | Value |
|---|---|
Series | Select PIKO MP plus. |
Type | Select the appropriate type/power class of the inverter. This automatically sets the maximum AC output power of the inverter. |
Serial interface | Select the RS485 interface to which the PIKO MP plus is connected to the KOSTAL Smart Energy Meter. |
Timeout | Accept the default value. |
Maximum output power | This value must be set for every connected inverter. Selecting the type/inverter power class automatically sets the inverter’s maximum output power. The maximum output power is the maximum power that the inverter to be configured is technically capable of delivering. |
Battery management | Enable battery support. |
Battery serial interface | Specifies the RS485 interface on the KOSTAL Smart Energy Meter to which the battery’s communication cable is connected. |
Battery type | Select the battery type, e.g. BYD HVM or BYD HVS. |
Number of modules | Select the number of modules installed in the battery. |
Max. SOC (State of Charge) | Set the maximum state of charge for the battery (default 100%). |
Min. SOC (State of Charge) | Set the minimum state of charge for the battery. Please refer to the battery manufacturer’s specifications (default 5%). |
Nominal battery charging/discharging power | This value is set automatically and does not need to be changed. It is calculated based on the battery type and the number of modules. However, it can be adjusted if the values do not match the battery specifications. |
Open advanced settings | |
RS485 address | Enter the inverter’s RS485 address. This must be unique for each device and must not be duplicated. |
- Press the Save button to adopt the settings.
- The PIKO MP plus and the battery have been set up in the KOSTAL Smart Energy Meter.