Device Manager
1 | Display of configured devices |
2 | Actions that can be performed on the devices |
3 | Add new devices |
4 | Viewing device details and measured values |
The Device Manager is used to set up and configure devices that are to be connected to the KOSTAL Smart Energy Meter G2, or to carry out a software update.
You can also view device details and current readings for the selected device here.
The devices set up here are displayed in the system overview and on the Home page.
INFO

Communication problems and incorrect readings
Devices must only be connected to the KSEM via a single connection at any one time.
For some devices, e.g. inverters with EEBus enabled, both interfaces are offered under ‘Add ’. For inverters, the Modbus connection should be selected here. An additional connection of the same inverter via EEBus will result in errors.
Setting up / adding devices in KSEM
Devices can be connected to the KOSTAL Smart Energy Meter via the ‘Add’ button.
- Click the ‘Add’ button.
- The ‘Add Device’ window will appear.
- To find devices on your home network that are accessible via Modbus-TCP, click the ‘Search for devices’ button. All devices found on the home network will then be displayed in the ‘Available devices’ list.
- Use the plus symbol (+) to select the device you wish to add.
- The ‘Add Device’ window opens.
- Fill in the blank fields and then click Connect. For further information on how to fill in the fields, see the table below.
- The device will be added to the system and shown as ‘Connected’ with a green tick. If a connection cannot be established, check the settings or the connection to the device.
- Device set up.
Adding devices manually
If the device cannot be found and does not appear in the ‘Available Devices’ list, it can also be added manually. This may also be the case, for example, with an ENECTOR G1 wallbox connected via RS485.
- Press the Add button.
- The ‘Add Device’ window will appear.
- Under ‘Add manually’, select the category and then the device type. Then click ‘Next’.
- The ‘Add Devices’ window opens.
- Fill in the empty fields and confirm your entries. Further information on how to complete the form can be found in the table below.
- The device will be added to the system and displayed with a green tick next to ‘Connection’. If no connection is established, check the settings or the connection to the device.
- Device set up
Add information about the inverter
Not all fields are displayed for every series of inverters. The display depends, for example, on the connection type (LAN or RS485) and whether a battery is connected.
Parameters | Explanation |
|---|---|
Series | Select the inverter series, e.g. PLENTICORE G3 inverter |
Type | Select the exact model of the device (e.g. PLENTICORE L G3 15 inverter). |
Category | Select the type of operation for the device. Not all categories are always displayed.
|
IP address | Enter the device’s IP address. This field only appears if the device is connected via LAN. |
Serial interface | Select the interface on the KSEM to which the device is connected. Only appears if the device is connected via RS485 (PIKO MP plus). |
Timeout | This value, in seconds, specifies the time after which an error message is issued to the configured device in the event of a communication fault. |
Control inverter | Default: Enabled Enabled: The inverter is controlled via the KSEM. Disabled: The inverter is not controlled but is displayed in the overview. This may be necessary when using MDC in the PLENTICORE G3 inverter. When using MDC in the PLENTICORE G3, no device needs to be configured in the KSEM. |
Max. AC output power of the inverter | This value must be set for every connected inverter. Selecting the type or power class of the inverter automatically sets the inverter’s maximum output power. The maximum output power is the maximum power that the inverter being configured is technically capable of delivering. The value for the maximum output power depends solely on the inverter type and model. The actual power output of the connected solar modules is not relevant for this setting. |
Advanced settings | The inverter’s Unit ID. This does not need to be changed. |
Advanced settings | RS485 address. This does not usually need to be changed. |
Information when adding wallboxes
Not all fields are displayed for every wallbox series. The display depends on the connection type: LAN (ENECTOR G2) or RS485 (ENECTOR G1).
Parameters | Explanation |
|---|---|
Name | Assign a name to the device |
IP address | Enter the device’s IP address. Only appears if the device is connected via LAN. |
Serial interface | Select the interface on the KSEM to which the device is connected. |
Slave address | RS485 address of the wallbox. Must not be changed. |
Phase rotation of the wallbox | Selection of the order of the connected phases. This must correspond to the physical connection configuration. |
Phases used | Three-phase: The wallbox is connected in a three-phase configuration. Single-phase: The wallbox is connected as single-phase. |
Phase connection | Default: The wallbox is connected in three-phase mode. Single-phase: The wallbox is connected as single-phase. |
Information when adding sensors
Not all fields are displayed for every series of sensors.
Parameter | Explanation |
|---|---|
IP address | Enter the device’s IP address. |
Unit ID | Enter the device’s UNIT ID. |
Name | Assign a name to the device |
Channel x | Assign a phase to the channel. |
Class | Select here whether a consumer or a generator is connected to the sensor. |
Type | Select a type from the list. |