KSEM with PLENTICORE and ENECTOR wallbox
When used in conjunction with a PLENTICORE or PLENTICORE BI, the following settings can be used to ensure that the Wallbox is prioritised over the home battery during charging.
The following settings are required for this:
- Add all inverters under System settings > Device manager in KSEM. For an inverter with a battery, ensure the correct category is selected (Photovoltaic with battery).
- Add the ENECTOR wallbox in KSEM.
- In the wallbox menu, you can set the priority to either the wallbox or the battery.
- If you are using a PLENTICORE with a battery and an ENECTOR, the power limit (no zero feed-in) can be configured in the inverter. Please note that if you wish to use Solar Pure Mode, the power reduction must not be less than the vehicle’s minimum charging power.
- If you have more than one inverter in the system (e.g. a PLENTICORE with a battery and a PLENTICORE acting as a PV inverter), set up the power limit in KSEM under System Settings > System Overview/Settings > Settings (cog icon) and take note of the changes to the settling time.