Adding KOSTAL inverters in the KOSTAL Smart Energy Meter
All KOSTAL inverters in a multiple-inverter connection that are to be measured and controlled using the KOSTAL Smart Energy Meter must be set up in the KOSTAL Smart Energy Meter.
Do this by performing the following steps:
- Call up online interface of KOSTAL Smart Energy Meter Calling up user interface
- Go to Inverter > Devices (manage the inverters used).
- Use the plus symbol to add an inverter.
INFO
When an inverter is selected, the predefined default values are adopted. These can be adapted if necessary.
Parameter | Value |
---|---|
Series | Select series (e.g. PIKO FW >= 5.00, PLENTICORE plus or PLENTICORE BI) |
Type | Select inverter |
Category | Choose category (e.g. photovoltaics for PIKO, photovoltaics with battery for PLENTICORE plus or battery for PLENTICORE BI) |
IP address | Enter the inverter's IP address. The IP address can be read on the inverter’s display. |
Maximum output power | Enter the inverter’s max. output power. This is required if a power limitation is to be set and calculated at the grid connection point. |
Open advanced settings | |
Unit ID | If using Unit ID, the default value 71 should be used. |
- Press the Save button to adopt the settings.
- Add more inverters using the same function.
- The inverter has been set up.
INFO
Incorrect time information during data transfer to the KOSTAL Solar Portal
Check the time and time zone set in the KOSTAL Smart Energy Meter and correct them if necessary. If the time is set incorrectly, the data will be transferred from KSEM with incorrect time information and will not be displayed correctly in the KOSTAL Solar Portal.