Adding KOSTAL inverters in the KOSTAL Smart Energy Meter

All KOSTAL inverters in a multiple-inverter connection that are to be measured and controlled using the KOSTAL Smart Energy Meter must be set up in the KOSTAL Smart Energy Meter.

Do this by performing the following steps:

  1. Call up online interface of KOSTAL Smart Energy Meter Calling up user interface
  2. Go to Inverter > Devices (manage the inverters used).
  3. Use the plus symbol to add an inverter.

INFO

Info

When an inverter is selected, the predefined default values are adopted. These can be adapted if necessary.

 

Parameter

Value

Series

Select series (e.g. PIKO FW >= 5.00, PLENTICORE plus or PLENTICORE BI)

Type

Select inverter

Category

Choose category

(e.g. photovoltaics for PIKO, photovoltaics with battery for PLENTICORE plus or battery for PLENTICORE BI)

IP address

Enter the inverter's IP address. The IP address can be read on the inverter’s display.

Maximum output power

Enter the inverter’s max. output power. This is required if a power limitation is to be set and calculated at the grid connection point.

Open advanced settings

Unit ID

If using Unit ID, the default value 71 should be used.

 

  1. Press the Save button to adopt the settings.
  2. Add more inverters using the same function.
  1. The inverter has been set up.

INFO

Info

Incorrect time information during data transfer to the KOSTAL Solar Portal

Check the time and time zone set in the KOSTAL Smart Energy Meter and correct them if necessary. If the time is set incorrectly, the data will be transferred from KSEM with incorrect time information and will not be displayed correctly in the KOSTAL Solar Portal.