Preparing PV connector
The inverter uses DC plug connectors of the Helios H4 type from Amphenol.
During installation, use the DC plug connectors supplied with the inverter. Using incompatible positive and negative metal contacts and DC plug connectors may have serious consequences. Any resultant damage to the device is not covered by warranty.
- During installation, it is essential that the current specifications of the manufacturer are observed.
Information about the Amphenol installation specification is available from: www.amphenol.com - Only use installation tools from the manufacturer.
- When mounting the sockets and plugs, ensure that the solar modules have the correct polarity. PV modules connected with the wrong polarity may cause thermal damage to the inverter.