Status LEDs

The LEDs on the front indicate the current operational status.

Further status information can be viewed using the KOSTAL PIKO CI Conf App or in the .

Measures to rectify events can be found in the chapter Event codes.

Meaning

State

Description

PV inputs

Lights up

The input voltage is within the operating range

Flashes

Overvoltage/undervoltage

Feed-in

Off

The inverter does not feed in

Lights up

The inverter feeds energy into the grid.

Every 30 seconds the inverter reports its current power:

flashes once: < 20 %

Flashes twice: < 40 %

Flashes 3x: < 60 %

Flashes 4x: < 80 %

Flashes 5x: < 100 %

Continuous flashing

The state of the power grid does not allow any feed-in.

Communication

Off

No connection active or no communication

Flashes

The inverter is communicating with another device.

Fault

Off

No fault

Lights up or flashes

A fault has occurred