KOSTAL PIKO CI app - menu structure

Deviations due to software versions are possible.

Event messages

Level 1

Event messages information

Generation

Level 1

Day/month/year energy

Basic settings

Level 1

Basic information

Type

Serial number

Firmware version

Internal code

Modbus version

Communication board version

Update CSB firmware

Update CB firmware

Operation

Switch on the inverter

Switch off the inverter

Reset to factory settings

Activate external shutdown

Data management

Export event messages

Export generation data

Export configuration

Configuration import

About

App version

User management

Level 1

Level 2

Change user

Log in as installer

Log in as system operator

Forgotten installer password (reset)

Change installer password for login

(only possible by installer)

 

Communication settings

Level 1

Level 2

WLAN settings

WLAN IP

Select WLAN connection

Change local WLAN password

LAN settings

IP mode

IP address

Subnet mask

Router/gateway

Auto DNS

DNS server 1

DNS server 2

RS485 settings

Baud rate

Data bit

Stop bit

Parity bit

Terminating resistor

Modbus address

Master/slave settings

Master/slave settings

Inverter settings

Level 1

Level 2

Level 3

Time setting

Synchronize inverter time

 

Grid settings

Frequency monitoring of level 1 activated

 

PV string monitoring

 

Grid guideline

 

Start up time (s)

 

Start up time following grid error (s)

 

Power gradient (%/min)

 

Power gradient following grid error (%/min)

 

Overfrequency limit value x (Hz)

 

Underfrequency limit value x (Hz)

 

Overvoltage limit value x (V)

 

Undervoltage limit value x (V)

 

Overfrequency switch-off time x time (s)

 

Underfrequency switch-off time x time (s)

 

Overvoltage switch-off time x time (s)

 

Undervoltage switch-off time x time (s)

 

Max. grid start voltage (V)

 

Min. grid start voltage (V)

 

Max. grid start frequency (Hz)

 

Min. grid start frequency (Hz)

 

Moving average

 

Power adaptation/controls

Active power control

P(U) regulation

P(F) regulation

Power gradient (%/s)

Maximum active power (%)

Maximum feed-in capacity (W)

With P(U) regulation active

P(U) start voltage node x (V)

P(U) power gradient node x Power (%)

P(U) set time (S)

With P(F) regulation active

P(f) overfrequency gradient (%)

Activation frequency (Hz)

Deactivation frequency (Hz)

P(f) underfrequency gradient (%)

Reactive power control

Settling time of reactive power

Reactive power mode

Energy management

Power limitation function

Sensor position

Modbus address of energy meter

Limitation of the active power to (W)

IP address of energy meter

L1-3 grid power

Total energy

Total feed-in energy

L1-3 consumer power

Total consumption

L1-3 inverter output

Total inverter output

Ripple control receiver (RCR)

Activate ripple control receiver

RCR active power (%)

RCR reactive power (%) / power factor cos phi

Other settings

Isolated network detection

 

Residual current monitoring

 

Type A RCD compatible

 

Shadow management

 

Shadow management interval time (s)

 

Insulation resistance (kOhm)

 

Leakage current limit (mA)

 

Limit for unbalanced voltage (%)

 

Dynamic grid support (FRT = Fault Ride Through)

Positive sequence K factor

Negative sequence K factor

Monitoring of supply voltage

Undervoltage ride through (V) UVRT

Overvoltage ride through (V) OVRT

Grid support mode

Limited grid support (%)

Irregular voltage change (%)

 

Overvoltage protection monitoring