Smart Communication Board (SCB)
1 |
X603 |
Not used. |
2 |
X1401 |
Not used. |
3 |
X1402 |
Not used. |
4 |
X401 |
Terminal for digital interface for ripple control receiver/external battery control |
5 |
X403 |
Terminal for ripple control receiver CEI for Italy. |
7 |
X402 |
SPD monitor input connection (evaluating external overvoltage protection). |
8 |
X452 |
Terminal for communication with the energy meter (KOSTAL Smart Energy Meter) via RS485. |
9 |
X171 |
USB connection (5 V, 500 mA). For service purposes only. |
10 |
X207 |
Ethernet connection (RJ45) LAN. |
11 |
X206 |
Ethernet connection (RJ45) LAN. |
The Smart Communication Board (SCB) is the communication and interface centre. All the connections for communicating with other components can be found on the SCB.