Info menu

On the Info page, the user can view events pending in the inverter and the inverter's installed version (e.g. software, MC, IOC, hardware). This information can also be viewed without logging in to the Webserver.

Device information – Devices

Shows information about the versions installed on the inverter. Information about the device can also be viewed without logging in to the Webserver.

Parameter

Explanation

Name

Name of inverter Can be changed by going to Settings > Basic settings.

Type designation

Inverter type designation

Serial number

Inverter serial number

Article number

Article number of the inverter

SW version

Software version (SW)

MC version

Main controller software version

IOC version

I/O controller software version

HW version

Hardware version

Insulation resistance R_iso

Insulation resistance measuring value

Guideline

The configured country setting for the inverter

Battery input

Status of the battery at DC input 3

Energy fed in in grid mode

Indicates in kWh the amount fed into the house grid in grid mode.

Run time in grid mode

Number of hours in grid mode

Energy in backup mode

Indicates in kWh the amount fed into the house grid in backup mode.

Run time in backup mode

Number of hours in backup mode.

Observe the maximum operating hours in backup mode. After 5000 hours in backup mode, the warranty expires because the components in the inverter are under significantly more load in microgrid operation than in grid mode.

Device information – Network

Provides information about the assigned network settings.

LAN parameter

Explanation

Network configuration

Static:

The network settings have been assigned manually.

DHCP:S

The network settings have been obtained automatically.

IPv4 address

Shows the specified IP address of the inverter

Subnet mask

Shows the specified subnet address

Gateway

Shows the router/gateway address

DNS server

Shows the address of the 1st and 2nd DNS server (Dynamic Name Server)

MAC address

Shows the physical address of the network interface

 

 

WLAN parameter

Explanation

Network configuration

WLAN off:

The inverter's WLAN interface is deactivated.

Access point:

The inverter offers a WLAN access point.

Client:

The inverter is a WLAN client and can connect to a WLAN gateway in the local home network.

Network information

Static:

The network settings have been assigned manually.

DHCP:

The network settings have been obtained automatically.

IPv4 address

Shows the specified IP address of the inverter

Subnet mask

Shows the specified subnet address

Gateway

Shows the router/gateway address

DNS server

Shows the address of the 1st and 2nd DNS server (Dynamic Name Server)

MAC address

Shows the physical address of the network interface

 

Solar portal parameters

Explanation

Last connection to the solar portal

Last transfer, shown in minutes or as a time

Device information – Events

Up to 10 events can be displayed. Additional information about the event can be displayed via Info (i) next to the event.