Info menu
On the Info page, the user can view events pending in the inverter and the inverter's installed version (e.g. software, MC, IOC, hardware). This information can also be viewed without logging in to the Webserver.
Device information – Devices
Shows information about the versions installed on the inverter. Information about the device can also be viewed without logging in to the Webserver.
Parameter | Explanation |
---|---|
Name | Name of inverter Can be changed by going to Settings > Basic settings. |
Type designation | Inverter type designation |
Serial number | Inverter serial number |
Article number | Article number of the inverter |
SW version | Software version (SW) |
MC version | Main controller software version |
IOC version | I/O controller software version |
Web app version | Webserver app version |
HW version | Hardware version |
Insulation resistance R_iso | Insulation resistance measuring value |
Guideline | The configured country setting for the inverter |
Display showing functions that have been released (e.g. battery input) | Display showing status (e.g. released) |
Battery SoH | Battery state of health as %. As a characteristic value of a battery, the battery state of health describes the battery’s level of ageing compared with its rated or new value and specifies this as a percentage. The value is only displayed if it is transmitted by the battery. |
Energy fed in in grid mode | Indicates in kWh the amount fed into the house grid in grid mode. |
Run time in grid mode | Number of hours in grid mode |
Energy in backup mode | Indicates in kWh the amount fed into the house grid in backup mode. |
Run time in backup mode | Number of hours in backup mode. Observe the maximum operating hours in backup mode. After 5000 hours in backup mode, the warranty expires because the components in the inverter are under significantly more load in microgrid operation than in grid mode. |
Licenses and legal information Information about Open Source software, developed by third parties and licensed using vehicles including GPL and/or LGPL. |
Device information – Network
Provides information about the assigned network settings.
LAN parameter | Explanation |
---|---|
Network configuration | Static: The network settings have been assigned manually. DHCP:S The network settings have been obtained automatically. |
IPv4 address | Shows the specified IP address of the inverter |
Subnet mask | Shows the specified subnet address |
Gateway | Shows the router/gateway address |
DNS server | Shows the address of the 1st and 2nd DNS server (Dynamic Name Server) |
MAC address | Shows the physical address of the network interface |
WLAN parameter | Explanation |
---|---|
Network configuration | WLAN off: The inverter's WLAN interface is deactivated. Access point: The inverter offers a WLAN access point. Client: The inverter is a WLAN client and can connect to a WLAN gateway in the local home network. |
Network information | Static: The network settings have been assigned manually. DHCP: The network settings have been obtained automatically. |
IPv4 address | Shows the specified IP address of the inverter |
Subnet mask | Shows the specified subnet address |
Gateway | Shows the router/gateway address |
DNS server | Shows the address of the 1st and 2nd DNS server (Dynamic Name Server) |
MAC address | Shows the physical address of the network interface |
Solar portal parameters | Explanation |
---|---|
Last connection to the solar portal | Last transfer, shown in minutes or as a time |
Device information – Events