Digital inputs
INFO

The settings in this menu can only be configured after logging in as the installer.
|
Parameter |
Function |
|---|---|
None | There is nothing connected to the digital inputs. |
Active power control | For the connection of a ripple control receiver with standard switching specifications. Detailed description in chapter Self-consumption. Active power control Activate the distribution of ripple control signals in the house grid. Activated: Deactivated: |
User-defined active/reactive power control | For the connection of a ripple control receiver. Unlike the standard active power control, here you can specify up to 16 settings. These are usually specified by the energy supply company. Detailed description in chapter Self-consumption. Active power control Activate the distribution of ripple control signals in the house grid. Activated: Deactivated: |
External battery management | If you have activated external control via the digital I/O ports in the Battery settings menu, you can define the functions of the inputs here. Assign the desired charge or discharge power to the inputs. |
Power limitation according to §14a EnWG | For connecting an FNN control box with standard switching specifications and additional control in accordance with Section 14a. Observe the instructions for the FNN control box provided by the manufacturer and whether the connections match the selection made here. In accordance with Section 14a, it must be possible for devices which draw energy from the public grid, such as heat pumps, wallboxes or a battery that is connected to the inverter and can be charged from the grid, to be limited by the energy supplier (power reduction). If power reduction is active, the current max. amount that can be drawn according to Section 14a is 4200 W. Ask your energy supply company what power limit you should set. Max. rated input (W): Activate Allocation of control signals for active/reactive power control. Activated: Deactivated: |
Power limitation with FNN control box | For connecting a FNN control box (connection via S1/S2/W3/W4) with standard switching specifications and additional control in accordance with Section 14a. Observe the instructions for the FNN control box provided by the manufacturer and whether the connections match the selection made here. In accordance with Section 14a, it must be possible for devices which draw energy from the public grid, such as heat pumps, wallboxes or a battery that is connected to the inverter and can be charged from the grid, to be limited by the energy supplier (power reduction). If power reduction is active, the current max. amount that can be drawn according to Section 14a is 4200 W. Ask your energy supply company what power limit you should set. Max. rated input (W): Activate Allocation of control signals for active/reactive power control. Activated: Deactivated: |