Overvoltage protection
Activate the evaluation of an external message signal. The inverter can evaluate the message output of the overvoltage modules (SPD) and output a message if an event occurs. Information on connection and wiring can be found under Connecting the signal contact for the external overvoltage protection (SPD – Surge Protective Device).
INFO

The settings in this menu can only be configured after logging in as the installer.
Parameter |
Explanation |
---|---|
Internal DC overvoltage protection detected | If type 2 internal DC overvoltage protection has been installed in the inverter, it is displayed here. |
Evaluation of the external message signal | Activate the function |
The monitor signal is interconnected as | Select overvoltage module switching status Normally open contact (NO) Normally, the contact is open. If an error occurs, the contact closes and the inverter issues a message. Normally closed (NC). Normally, the contact is closed. If an error occurs, the overvoltage module's contact opens and the inverter issues a message. |