Create LAN direct connection between inverter/computer

This variant is mainly used when configuring using the Webserver on site.

DANGER

danger

Risk of death due to electrical shock and discharge!

  • De-energise device and secure against being switched on again.

INFO

Info

Use a patch cable of category 5 (Cat 5e) or better with a length of max. 100 m.

INFO

Info

If the inverter is connected directly to the PC and has not yet been given its own IP address via a DHCP server, an IP address must be configured manually for the inverter in the inverter itself. This can then be entered into the browser's address bar on the PC to access the Webserver.

Connecting the Ethernet cable to a router integrates the inverter into your own network and the inverter can then be contacted by all computers incorporated in the same network.

1

Connect inverter with Ethernet cable

2

Smart Communication Board with LAN interface

3

Ethernet cable (LAN)

4

PC

5

Router

Connect inverter with router or computer

  1. Turn the DC switch on the inverter to OFF.
  2. Switch off inverter AC line circuit breaker and secure it against being switched on again.
  3. Remove the cover.
  4. Remove the terminal compartment's cover.
  5. Insert Ethernet cable into the inverter and seal with sealing ring and union nut. Tighten union nut to the prescribed torque. Tightening torque: 8 Nm (M25).
  6. Connect Ethernet cable to LAN interface of Smart Communication Board.
  7. Connect Ethernet cable to a router or computer.
  8. Close cover of terminal compartment and inverter (2.0 Nm).
  9. Activate fuses and DC switch.
  1. The inverter is connected to the computer.