Setting up the ENECTOR G2 wallbox
The ENECTOR G2 wallbox can only be controlled via the PLENTICORE G3 if all devices can be controlled via the inverter.
It is not possible to use a combination of the PLENTICORE G3 and the KOSTAL Smart Energy Meter G2 for control, as this will result in errors.
To ensure the ENECTOR G2 wallbox can be controlled via the PLENTICORE G3, it must be added in the device manager of the inverter, which is configured as an MDC host.
- Open the web server of the PLENTICORE G3 that has been configured as an MDC host.
- Select the ‘Device Manager ’ menu item.
- Refresh the list by clicking ‘Refresh’.
- If the wallbox is displayed, you can click on it to open the Device Details view. If the wallbox is not displayed, it can be added to the system via ‘Add Manually ’.
- In the Device Details view, fill in the empty fields and then click Connect.
- Name: Name of the wallbox
- Device class: Wallbox
- Manufacturer: KOSTAL
- Type: ENECTOR AC 3.7/11 G2
- IP: IP address of the wallbox
- The wallbox will be added to the system and displayed with a green tick once a connection to the wallbox has been established. If a connection cannot be established, please check the settings or the connection to the wallbox.