Smart Communication Board (SCB)

1

X603

Not used.

2

X1401

Potential-free switched outputs OUT 1 and OUT 2 (NO or NC contact)

Loadable up to max. 24 V, 100 mA (ext. power supply unit required for supply).

3

X1402

Potential-free switched outputs OUT 3 and OUT 4 (NO or NC contact)

Loadable up to max. 24 V, 100 mA (ext. power supply unit required for supply).

4

X401

Terminal for digital interface for ripple control receiver/external battery control

5

X403

Terminal for ripple control receiver CEI for Italy.

6

X601

Battery communication terminal.

7

X402

SPD monitor input connection (evaluating external overvoltage protection).

8

X452

Terminal for communication with the energy meter (KOSTAL Smart Energy Meter) via RS485.

9

X171

USB connection (5 V, 500 mA). For service purposes only.

10

X207

Ethernet connection (RJ45) LAN.

11

X206

Ethernet connection (RJ45) LAN.

The Smart Communication Board (SCB) is the communication and interface centre. All the connections for communicating with other components can be found on the SCB.