Menu – Settings/information
The inverter and additional components (e.g. energy meter) are configured under "Settings/information".
- Basic setting
Setting the general parameters.
Parameter | Explanation |
---|---|
Language | Selection of menu language |
Inverter name | Enter the inverter name. The characters a–z, A–Z, 0–9 and "-" are permitted for the name change. Spaces or special characters are not possible. The browser connection to the Webserver can be established with the new name following the name change. It is still possible to gain access with the serial number. |
Date/time | Enter the time and date. Setting the time zone Activate/deactivate or automatic determination of time. The NTP server can be configured via the Webserver. |
- Communication
Set the communication parameters for the inverter's Ethernet connection.
INFO
The "Automatic" option is activated by default. This means that the inverter acquires its IP address from a DHCP server or automatically generates an IP address.
If the inverter is not allocated an automatic IP address through a DHCP server, the inverter can be configured using the item Manual.
The data necessary for configuration, such as IP, router addresses etc., can be found on your router/gateway.
Parameter |
Explanation |
---|---|
Network IPv4 | Activate the network protocol and configure the network interface (Ethernet) for the inverter. The Automatic option is activated by default. If configuring manually, the corresponding parameter values should be entered. |
Setting the DNS server: The Automatic option is activated by default. If configuring manually, the corresponding parameter values should be entered. | |
Wifi settings | Setting the communication parameters for the inverter's Wifi connection. The inverter offers various options here. |
Wifi mode: Wifi off The inverter's Wifi interface is deactivated. | |
Wifi mode: Access point The inverter offers a Wifi access point. This can be used, for example, to log a PC or smartphone on to the inverter to configure or monitor the inverter. SSID: Displays the inverter's SSID. The SSID is KOSTAL_<serial number>. SSID visible: The SSID is visible to other devices in the Wifi search. Encryption: Select Wifi encryption. Password: Enter a password. By default, this is the article number found on the type plate. Radio channel: Select the radio channel. By default, this should be set to "Auto". QR code: Displays the data as a QR code. Scan the code with a smartphone and connect to the inverter. | |
Wifi mode: Client The inverter is a Wifi client and can connect to a Wifi gateway in the local home network. In that case, a LAN connection no longer needs to be set up. Find networks: Press the button to search for available networks in the vicinity of the inverter. The available networks in the vicinity of the inverter are then displayed. Select your local network to which the inverter should connect. SSID: If the network you are looking for is not displayed, this may be because it has been configured to not be visible. You can then enter the network name yourself here. | |
Wifi IPv4 | Configuration of the inverter's Wifi network interface. The Webserver on the inverter can be accessed via this IP address if there is a Wifi connection to the inverter. The Automatic option is activated by default. If configuring manually, the corresponding parameter values should be entered. |
Setting the DNS server: The Automatic option is activated by default. If configuring manually, the corresponding parameter values should be entered. | |
Modbus/SunSpec (TCP) |
Activates the SunSpec (TCP) protocol |
- Solar portal
Input for the solar portal configuration. If a solar portal is to be used, the log data and events are sent to the solar portal.
Parameter | Explanation |
---|---|
Solar portal | Selection of solar portal. |
Activate | Activate to start sending to a solar portal. |
- Device information
Shows information about the versions installed on the inverter.
Parameter | Explanation |
---|---|
Article number | Article number of the inverter |
Serial number | Inverter serial number |
Hardware | Hardware version |
MC | Main controller version |
IOC | Input-output controller version |
SW | Software version |
National guideline | Shows the national guideline selected for the inverter. |
Max. output power | Shows the inverter's maximum output power. |
- Extra options
This function can be used to release additional options/functions for the inverter.
Parameter | Explanation |
---|---|
Release option | Enter an activation code, e.g. to connect a battery. This must be purchased in advance from the KOSTAL Solar Webshop. |
Released options | Overview of options currently released in the inverter |
INFO
The activation code can be purchased from the KOSTAL Solar Webshop.
The following link will take you to the shop: shop.kostal-solar-electric.com
- Service menu
The installer or an experienced user can use the inverter's service menu to implement settings on the inverter.
INFO
The service menu items depend on the inverter software installed and may differ from the description here.
Some menu items can also be run without a service password. However, these items should only be run by experienced users because otherwise under certain circumstances the inverter may no longer function perfectly.
For the complete service menu to be displayed, the installer must request a code from the inverter manufacturer's service team.
The code is entered by going to the Service code input menu item.
Once the service code has been entered and confirmed, additional service menu entries appear.
Parameter | Explanation |
---|---|
Service code input | Input of service code and enabling of additional menu items. |
Fan test | Starting the fan test |
Reset settings | Reset inverter to factory settings. This resets the following settings: Language, inverter name, date/time, network settings, protocol, log data and solar portal. |
Event list | Shows the last 10 events with date. Selecting an event and pressing the "OK" key displays a detailed view of the event. |
Energy management |
|
Reset national guideline | Reset the country setting. After resetting, the inverter starts the commissioning wizard after a restart.
|
- Update menu
The update menu can be used to set the software update method or to install updates manually.
INFO
You can find the latest update in the download area for the product on our website at www.kostal-solar-electric.com
Parameter | Explanation |
---|---|
System update | Select the inverter's system update method (software update).
|
Look for updates | The system looks for current updates from the manufacturer. If a new update is available, it is displayed and can then be installed. |