Webserver menu – Current values
Menu items to display the current energy values of the AC and DC side.
- PV generator
Shows the generated voltage, current and energy of the PV generators per DC input.
Parameter |
Explanation |
---|---|
DC input x |
Shows the generated voltage, current and power of the PV generators per DC input. |
- Inverter
Shows the current status of the inverter, current performance data of the grid side (AC) and how the energy is distributed to the phases.
Parameter |
Explanation |
---|---|
Status |
Inverter operational status. For more information, see Operational status (display) |
Digital inputs |
Signal status of digital interface terminal for ripple control receiver (input 1-4). The display shows whether the feed-in is currently limited, e.g. by the energy supplier or by an external battery management system. Settings, e.g. for user-defined active/reactive power reduction, can be made by going to Service menu > Digital inputs. Why active power control? |
Output power |
Shows how much inverter power is being fed into the home network. |
Grid frequency |
Shows the current grid frequency |
Cos phi |
Indicates the current power factor (cos phi) |
Limitation on |
Shows the current power curtailment setting. If an energy meter (e.g. a KOSTAL Smart Energy Meter) is fitted in the house grid and power limitation is set, the active power is dynamically limited taking home consumption into consideration. This means that in addition to the set power curtailment, the home consumption is added up to the maximum power limit of the inverter. |
Phase x |
Shows the power values per phase (x = 1, 2 or 3) |
- House consumption
Display of the current home consumption and the sources from which home consumption is covered.
INFO
In a device network comprising multiple KOSTAL inverters, the data is merged in the portal. Correct and complete visualisation takes place exclusively in the KOSTAL Solar Portal and in the KOSTAL Solar App and not in the individual inverter.
Parameter |
Explanation |
---|---|
Current home consumption covered by |
Shows the home consumption and the source from which it is currently covered. |
- Grid
Shows the current performance data of the grid side (AC).
Parameter |
Explanation |
---|---|
Grid |
Feed-in: PV energy is fed into the public grid. Consumption: Energy is purchased from the public grid to cover home consumption. |
- Battery
If a battery is connected to the inverter (only possible if DC3 has been released), the current battery values are displayed.
INFO
If all values are at zero, the battery is in sleep mode. You can check the status of the battery by going to Current values > Inverter.
Parameter |
Explanation |
---|---|
Status |
Charge: The battery is being charged. Discharge: Energy is being drawn from the battery. |
Battery status |
Normal:
Equalisation charge:
Deep discharge protection:
Ext. battery control:
Battery sleep mode:
Service charging:
|
Voltage |
Shows the battery's charge/discharge voltage. |
Current |
Shows the battery's charge/discharge current. |
Power |
Shows the battery's charge/discharge power. |
Charging status |
Shows the battery's charging status in %. |
Charging cycles |
Shows the battery's charging cycles. |