Current values menu

The different statistics show the user the current energy values on the AC and DC side for the daily, monthly, annual and total yield. Detailed information can be displayed by expanding the statistics.

 

PV generator

Shows the generated voltage, current and energy of the PV generators per DC input.

Parameter

Explanation

DC input x

Shows the generated voltage, current and power of the PV generators per DC input.

 

Inverter

Displays the current status of the inverter and the current performance data of the grid side (AC) and how the energy is distributed across the phases.

Parameter

Explanation

Status

Operating status of the inverter.

For more information, visit Operational status (display)

Digital inputs

Signal status of the connection terminal Digital interface for ripple control receivers (inputs 1–4). The display shows whether the feed-in, e.g. from the energy supplier or an external battery management system, is currently being limited. Settings, e.g. for user-defined active/reactive power reduction, can be made under Service > General > Digital inputs. Why active power control?

Output power

Shows how much power the inverter is feeding into the domestic grid.

Grid frequency

Shows the current grid frequency.

Cos phi

Indicates the current power factor (cos phi).

Power reduction to

Shows the current power curtailment setting.

If an energy meter (e.g. a KOSTAL Smart Energy Meter) is installed in the home network and a power limit is set, the active power is dynamically limited taking into account the home consumption. This means that, in addition to the set power curtailment, the home consumption is added up to the maximum power limit of the inverter.

Phase x

Displays the power values per phase (x = 1, 2 or 3)

 

House consumption

Display of the current home consumption and the sources from which home consumption is covered.

INFO

Info

In a device network comprising multiple KOSTAL inverters, the data is merged in the portal. Correct and complete visualisation takes place exclusively in the KOSTAL Solar Portal and in the KOSTAL Solar App and not in the individual inverter.

Parameter

Explanation

Current home consumption covered by

Shows the home consumption and the source from which it is currently covered.

 

Grid

Shows the current performance data of the grid side (AC).

Parameter

Explanation

Grid

Feed-in: PV energy is fed into the public grid.

Consumption: Energy is purchased from the public grid to cover home consumption.

 

Battery

INFO

Info

If all values are at zero, the battery is in sleep mode. You can check the status of the battery by going to Current values > Inverter.

Parameter

Explanation

Status

Charge: The battery is being charged.

Discharge: Energy is being drawn from the battery.

Battery status

Normal:
Normal state

Equalisation charge:
The battery is charged from the grid for protection.

Deep discharge protection:
The battery is charged from the grid to protect against deep discharge.

Ext. battery control:
The battery is regulated via an external control system.

Battery sleep mode:
If the battery charging status falls below the configured minimum SoC, this status is displayed and the battery is disconnected from the system. As soon as sufficient excess PV power is available, sleep mode is cancelled and the battery is switched on again.

Service charging:
Service charging can only be started by the installer.

Voltage

Shows the battery's charge/discharge voltage.

Current

Shows the battery's charge/discharge current.

Power

Shows the battery's charge/discharge power.

Charging status

Shows the battery's charging status in %.

Charging cycles

Shows the battery's charging cycles.