Digital inputs

INFO

Info

The settings in this menu can only be configured after logging in as the installer.

Parameter

Function

None

There is nothing connected to the digital inputs.

Active power control

For connecting a ripple control receiver with standard switching specifications.

Detailed description in the chapter on own consumption. Active power control

Activates the distribution of ripple control signals in the home network.

Enabled:
If a ripple control receiver is connected to the inverter, the control signals from this ripple control receiver are distributed via UDP in the local LAN network. This means that other inverters can also be controlled via the connected ripple control receiver.

Deactivated:
The control signals are not distributed via UDP in the local LAN network.

Distribution of control signals for active/reactive power control:
If the control signals are to be distributed via UDP in the local LAN network (home network), activate the distribution of the broadcast control signals. This allows other inverters in the local LAN network to also be controlled.

Custom active/reactive power control

For connecting a ripple control receiver. Unlike standard active power control, this option allows you to specify up to 16 settings. These are usually specified by the energy supplier.

Detailed description in the chapter on own consumption. Active power control

Activates the distribution of ripple control signals in the home network.

Enabled:
If a ripple control receiver is connected to the inverter, the control signals from this ripple control receiver are distributed via UDP in the local LAN network. This means that other inverters can also be controlled via the connected ripple control receiver.

Deactivated:
The control signals are not distributed via UDP in the local LAN network.

Distribution of control signals for active/reactive power control:
If the control signals are to be distributed via UDP in the local LAN network (home network), activate the distribution of the broadcast control signals. This allows other inverters in the local LAN network to also be controlled.

External battery management

If you have activated external control via the digital I/O ports in the Battery settings menu, you can define the functions of the inputs here. Assign the desired charge or discharge power to the inputs.