Menu – Settings/information
The inverter and additional components (e.g. energy meter) are configured under "Settings/information".
Basic setting
Setting the general parameters.
Parameter | Explanation |
|---|---|
Language | Selection of menu language |
Inverter name | Enter the inverter name. The characters a–z, A–Z, 0–9 and "-" can be used when changing the name. Spaces or special characters are not possible. The browser connection to the Webserver can be established with the new name following the name change. It is still possible to gain access with the serial number. |
Date and time | Enter the time and date. Setting the time zone Activate/deactivate or automatic determination of time. The NTP server can be configured via the Webserver. |
Communication
Set the communication parameters for the inverter's Ethernet connection.
INFO

The "Automatic" option is activated by default. This means that the inverter acquires its IP address from a DHCP server or automatically generates an IP address.
If the inverter is not allocated an automatic IP address through a DHCP server, the inverter can be configured using the item Manual.
The data necessary for configuration, such as IP addresses, router addresses etc., can be found on your router/gateway.
|
Parameter |
Explanation |
|---|---|
Network IPv4 | Activate the network protocol and configure the network interface (Ethernet) for the inverter. The Automatic option is activated by default. If configuring manually, the corresponding parameter values should be entered. |
Setting the DNS server: The Automatic option is activated by default. If configuring manually, the corresponding parameter values should be entered. | |
WLAN settings | Setting the communication parameters for a WLAN connection of the inverter. The inverter offers various options here. |
WLAN mode: WLAN off The inverter's WLAN interface is deactivated. | |
WLAN mode: Access point The inverter offers a WLAN access point. This can be used, for example, to connect a PC or smartphone to the inverter for configuration or monitoring purposes. SSID: Display of the inverter's SSID. The SSID consists of KOSTAL_ and the serial number of the inverter, e.g. KOSTAL_91109ADE00053. SSID visible: The SSID is visible to other devices during WLAN searches. Encryption: Selection of the Wi-Fi encryption. Password: Enter a password. By default, this is the password item number, which can be found on the type plate. Radio channel: Select the radio channel. By default, this should be set to "Auto". | |
WLAN mode: Client The inverter is a Wi-Fi client and can connect to a Wi-Fi gateway in the local home network. In this case, it is no longer necessary to set up a LAN connection. Available networks: Press the button to search for available networks in the vicinity of the inverter. The available networks in the vicinity of the inverter are then displayed. Select your local network to which the inverter should connect. SSID: If the network you are looking for is not displayed, it may be because the network has been configured as invisible. In this case, you can enter the network name yourself. Password: Enter the password for the Wi-Fi network. | |
WLAN IPv4 | Configuration of the inverter's WLAN network interface. The Webserver on the inverter can be accessed via this IP address if there is a WLAN connection to the inverter. The Automatic option is activated by default. If configuring manually, the corresponding parameter values should be entered. |
Setting the DNS server: The Automatic option is activated by default. If configuring manually, the corresponding parameter values should be entered. | |
Network bridge | The Wi-Fi – LAN bridge can be used in the Wi-Fi modes Access Point and Client. Additional devices can be connected to the LAN interface of the inverter, which serves as a Wi-Fi-LAN bridge. Data is then sent via the Wi-Fi interface to the router and into the Internet. Devices connected to the inverter must not be connected to another DHCP server through which they could receive network data (e.g. IP addresses). |
Modbus SunSpec (TCP) | Activate the Modbus SunSpec (TCP) protocol |
WLAN connection code | The QR code for the inverter access point is output using this menu item. The direct connection can be used to connect with the smartphone and inverter. The Webserver can then be called up on the inverter using a web browser and by entering the inverter’s IP address 192.168.67.1. The IP address is also shown on the inverter display. |
EEBus configuration | You can activate the EEBus protocol on the inverter via this menu item. Devices EEBus QR code |
Solar portal
Input for the solar portal configuration. If a solar portal is to be used, the log data and events are sent to the solar portal.
Parameter | Explanation |
|---|---|
Solar portal | Selection of solar portal. |
Activate | Activate to start sending to a solar portal. |
Device information
Shows information about the versions installed on the inverter.
Parameter | Explanation |
|---|---|
Article number | Article number of the inverter |
Serial number | Inverter serial number |
Hardware | Hardware version |
MC | Main controller version |
IOC | Input-output controller version |
SW | Software version |
National guideline | Country guidelines selected for the inverter |
Max. grid feed-in | The configured maximum power that can be fed into the public grid |
Insulation resistance | Measured insulation resistance value |
Extra options
This function can be used to release additional options/functions for the inverter.
Parameter | Explanation |
|---|---|
Release option | Enter an activation code, e.g. to connect a battery. This must be purchased in advance from the KOSTAL Solar Webshop. |
Released options | Overview of options currently released in the inverter |
INFO

The activation code can be purchased from the KOSTAL Solar Webshop.
You can access the shop via the KOSTAL Solar Terminal or by using this link: shop.kostal-solar-electric.com
Service menu
The installer or an experienced user can use the inverter's service menu to implement settings on the inverter.
INFO

The service menu items depend on the inverter software installed and may differ from the description here.
Some menu items can also be run without a service password. However, these items should only be run by experienced users because otherwise under certain circumstances the inverter may no longer function perfectly.
For the complete service menu to be displayed, the installer must request a code from the inverter manufacturer's service team.
The code is entered by going to the Service code input menu item.
Once the service code has been entered and confirmed, additional service menu entries appear.
Parameter | Explanation |
|---|---|
Service code entry | Enter the service code provided by an installer to activate the additional menu items. The service code can be obtained by installers from our service department. |
Fan test | Start fan test |
Reset settings | Reset the inverter to factory settings. The following settings will be reset: language, inverter name, date/time, network settings, protocol, log data and solar portal. |
Event list | Display of the last 10 events with date. Select an event and press the "OK" button to display a detailed view of the event. |
Device restart | Restart the inverter. |
Additional menu items after entering the service code
Parameter | Explanation |
|---|---|
Grid connection |
|
Reset national guidelines | Reset the country setting. After resetting, the inverter starts the commissioning wizard after a restart.
|
Update menu
The update menu can be used to set the software update method or to install updates manually.
INFO

You can find the latest update in the download area for the product on our website at www.kostal-solar-electric.com
Parameter | Explanation |
|---|---|
System update | Select the inverter's system update method (software update).
|
Check for updates | The system looks for current updates from the manufacturer. If a new update is available, it is displayed and can then be installed. |