Activating active power control
- Connect the inverter and computer. Connecting methods between inverter/computer
- Start your internet browser.
- Enter the IP address of the inverter to which the ripple control receiver is connected in the address bar of the browser and confirm with Return.
INFO

The IP address can be found on the inverter display.
- The web server page will open.
- Log in to the web server as an installer.
- Select the menu item Service > General > Digital inputs.
- The Digital Inputs page opens.
- Select the Active power control function.
- If the control signals of this ripple control receiver are to be distributed via UDP in the local LAN network (home network), activate the item Activate distribution of ripple control signals. This allows other inverters to be controlled via the connected ripple control receiver in the local LAN network.
- Click on the Save button.
- Active power control is now active.