Connecting battery's DC cables

The DC cables of the battery may only be connected to the inverter when the inverter and the battery storage system are de-energised.

DANGER

danger

Risk of death due to electrical shock and discharge!

The battery’s DC cables may be energised.

  • Be sure to de-energise the battery storage system. Please also observe the instructions in the operating manual provided by the battery manufacturer.

INFO

Info

Use flexible and tin-plated cables with double insulation according to EN 50618.

We recommend a cross-section of 6mm². Please observe the specifications of the plug manufacturer and the technical data for the inverter.

  1. Disconnect the battery storage unit and inverter from the power supply.
  2. Connect the plug to the positive cable and the socket to the negative cable in accordance with the relevant standards. The inverter is equipped with connectors from PHOENIX CONTACT (type SUNCLIX). When installing, it is essential to observe the manufacturer's current specifications (e.g. permissible tightening torque, etc.).
    Information on the SUNCLIX installation instructions can be found at: www.phoenixcontact.com
  3. When installing the sockets and plugs on the DC cables of the battery, ensure that the polarity is correct!
  4. Plug the sockets and plugs of the battery's DC cables into the inverter. Keep the sealing plugs from the connectors.
  5. The configuration and selection of the battery type must be carried out on the web server after the initial installation.
  1. The DC cables of the battery are connected.