Log file: Entries

The units of physical quantities are followed by various entries in the log file.
The following table explains the various entries in the log file and may vary depending on the model:

Entry

Explanation

Time

Time in seconds since the inverter was started up

DC x U

DC voltage: Input voltage of the respective string (x = 1, 2 and 3) in V

DC x I

DC current: Input current of the respective string (x = 1, 2 and 3) in mA

DC x P

DC power: Input power of the respective string (x = 1, 2 and 3) in W

DC x T

DC temperature: Information for service. Temperature of the respective phase (x = 1, 2 and 3) in digital values

DC x S

DC status: Information for servicing the respective strings (x = 1, 2 and 3)

AC x U

AC voltage: Output voltage of the respective phase (x = 1, 2 and 3) in V

AC x I

AC current: Output current of the respective phase (x = 1, 2 and 3) in mA

AC x P

AC power: Output power of the respective phase (x = 1, 2 and 3) in W

AC x T

AC temperature: Information for service. Temperature of the respective phase (1, 2 and 3) in digital values

AC F

AC frequency: Mains frequency in Hz

FC I

Fault current: Measured fault current in mA

AIn1-4

Not used

AC S

AC status: Information for servicing the operating status of the inverter

ERR

General faults

ENS S

Status of the ENS (grid monitoring device with assigned switching elements):

Status of grid monitoring

ENS Err

Faults in the ENS (network monitoring device with assigned switching devices)

SH x P

Power of the external current sensor: Power of the respective phase (x = 1, 2 and 3) in W

SC x P

Own consumption on the respective phase (x = 1, 2 and 3) in W

HC1 P

HC2 P

HC3 P

Not used

Household consumption in W from the PV modules

Household consumption in W from the grid

SOC H

Battery state of charge (SoC)

BAT Te

Battery temperature

BAT Cy

Number of battery charge cycles

KB S

Internal communication status when connected to AC mains

Total E

Total energy in kWh generated by the inverter and fed into the AC grid in the house.

OWN E

Own consumption: Current energy consumption in kWh in the household, which is covered by the inverter.

HOME E

Household consumption: Current energy consumption in kWh in the household, which is covered by the inverter and from the AC grid.

Iso R

Insulation resistance in kOhm when connected to the AC grid.

Event

POR (Power On Reset) event: Communication restarts after a loss of AC voltage.