Log file: Entries
The units of physical quantities are followed by various entries in the log file.
The following table explains the various entries in the log file and may vary depending on the model:
Entry | Explanation |
|---|---|
Time | Time in seconds since the inverter was started up |
DC x U | DC voltage: Input voltage of the respective string (x = 1, 2 and 3) in V |
DC x I | DC current: Input current of the respective string (x = 1, 2 and 3) in mA |
DC x P | DC power: Input power of the respective string (x = 1, 2 and 3) in W |
DC x T | DC temperature: Information for service. Temperature of the respective phase (x = 1, 2 and 3) in digital values |
DC x S | DC status: Information for servicing the respective strings (x = 1, 2 and 3) |
AC x U | AC voltage: Output voltage of the respective phase (x = 1, 2 and 3) in V |
AC x I | AC current: Output current of the respective phase (x = 1, 2 and 3) in mA |
AC x P | AC power: Output power of the respective phase (x = 1, 2 and 3) in W |
AC x T | AC temperature: Information for service. Temperature of the respective phase (1, 2 and 3) in digital values |
AC F | AC frequency: Mains frequency in Hz |
FC I | Fault current: Measured fault current in mA |
AIn1-4 | Not used |
AC S | AC status: Information for servicing the operating status of the inverter |
ERR | General faults |
ENS S | Status of the ENS (grid monitoring device with assigned switching elements): Status of grid monitoring |
ENS Err | Faults in the ENS (network monitoring device with assigned switching devices) |
SH x P | Power of the external current sensor: Power of the respective phase (x = 1, 2 and 3) in W |
SC x P | Own consumption on the respective phase (x = 1, 2 and 3) in W |
HC1 P HC2 P HC3 P | Not used Household consumption in W from the PV modules Household consumption in W from the grid |
SOC H | Battery state of charge (SoC) |
BAT Te | Battery temperature |
BAT Cy | Number of battery charge cycles |
KB S | Internal communication status when connected to AC mains |
Total E | Total energy in kWh generated by the inverter and fed into the AC grid in the house. |
OWN E | Own consumption: Current energy consumption in kWh in the household, which is covered by the inverter. |
HOME E | Household consumption: Current energy consumption in kWh in the household, which is covered by the inverter and from the AC grid. |
Iso R | Insulation resistance in kOhm when connected to the AC grid. |
Event | POR (Power On Reset) event: Communication restarts after a loss of AC voltage. |