Battery usage

If a battery is connected to the inverter, usage of the battery can be configured here.

The following options can be used to optimise battery usage:

Parameter

Explanation

No optimisation

The battery is used as normal for charging and discharging. All other settings should be configured under the battery settings.

Time-controlled battery usage

There are times when electricity costs are relatively high (different tariff models). It may therefore make sense to allow the battery to discharge during these periods and to allow charging outside these periods.

The times set here can be overridden by specifications from an activated external battery management system.

No restriction:
No conditions have been set for this period.

 

Battery charging blocked, discharging permitted for domestic use:
The battery is not charged during this period. However, discharging the battery for domestic use is permitted.

Battery discharge blocked, charging permitted when there is excess energy:
The battery is not discharged during this period. However, as soon as there is excess energy, the battery is charged.

 

NOTE! Please note whether local guidelines permit charging the storage unit from the public grid. If in doubt, ask your installer.