System overview
The PLENTICORE MP G3 is a single-phase hybrid inverter. The inverter can be used in single-phase and three-phase grids. Local requirements relating to phase imbalance must be heeded.
The inverter can be used as follows.
As a PV inverter
If the inverter is used as a pure PV inverter, only PV generators are connected to the DC inputs. There must be at least one PV generator connected to the inverter.
The energy generated can be used for self-consumption in the house grid or is fed into the public grid.
1 | Communication link for inverter via LAN |
2 | Communication link for inverter via WLAN/WiFi |
3 | Inverter |
4 | PV generators |
5 | Line circuit breaker for inverter |
6 | Digital energy meter (Modbus RTU) at the grid connection point |
7 | Main fuse for building |
8 | Procurement and feed meter or smart meter (not in all countries) |
9 | Public grid |
10 | Line circuit breaker for energy consumers |
11 | Energy consumers |
Hybrid inverter (product upgrade required)
If the inverter is being used as a hybrid inverter, PV generators and a battery are connected to the inverter.
For the battery to be detected at the DC input for the battery, the battery function product upgrade must be activated in the inverter using an activation code.
The inverter is used to directly provide energy for self-consumption or to store surplus energy in the battery storage unit. The stored energy can be used for self-consumption in the house grid. Surplus energy that can no longer be stored is fed into the public grid.
In addition, energy from other AC energy suppliers (park controllers), e.g. PV systems, combined heat and power (CHP) units or small wind turbines, can be temporarily stored.
1 | Communication link for inverter via LAN |
2 | Communication link for inverter via WiFi/WLAN |
3 | Inverter |
4 | PV generators |
5 | Connection for battery system (available as option after activation) |
6 | Communication link for battery management system |
7 | Line circuit breaker for inverter |
8 | Digital energy meter (Modbus RTU) at the grid connection point |
9 | Main fuse for building |
10 | Procurement and feed meter or smart meter (not in all countries) |
11 | Public grid |
12 | Line circuit breaker for energy consumers |
13 | Energy consumers |
14 | Feed meter for AC power source |
15 | Line circuit breaker for AC power source |
16 | AC power source, e.g. combined heat and power (CHP) unit, or other generation plants, such as PV inverter (the energy from the AC power source can be temporarily stored in the battery) |
Battery inverter (product upgrade required)
If the inverter is used as a pure battery inverter, a battery can be connected to the last DC input (BAT).
For the battery to be detected at the DC input for the battery, the battery function product upgrade must be activated in the inverter using an activation code.
The inverter with connected battery storage is used to store energy from energy suppliers (park controllers) produced in the house grid, e.g., by other PV systems, combined heat and power (CHP) units or small wind turbines. The stored energy can then be used for self-consumption in the house grid.
There is the option to connect PV generators to the free DC inputs (hybrid inverter).
1 | Communication link for inverter via LAN |
2 | Communication link for inverter via WiFi/WLAN |
3 | Inverter |
4 | Battery system connection |
5 | Communication link for Battery Management System (BMS) via RS485 |
6 | Line circuit breaker for inverter |
7 | Digital energy meter (Modbus RTU) at the grid connection point |
8 | Main fuse for building |
9 | Procurement and feed meter or smart meter (not in all countries) |
10 | Public grid |
11 | Line circuit breaker for power consumption |
12 | Power consumption |
13 | Feed meter for AC power source |
14 | Line circuit breaker for AC power source |
15 | AC power source, e.g. CHP unit, or other generation plants, such as PV inverter (the energy from the AC power source can be temporarily stored in the battery) |
Inverter with KOSTAL ENECTOR wallbox
If the inverter and a KOSTAL ENECTOR wallbox are fitted in the system environment, a KOSTAL Smart Energy Meter (KSEM) must be used as the energy meter.
The KSEM is a three-phase energy meter but is run on only one phase when combined with the PLENTICORE MP G3.
1 | Communication link for inverter via LAN |
2 | Communication link for inverter via WiFi/WLAN |
3 | Inverter |
4 | PV generators |
5 | Connection for battery system (available as option after activation) |
6 | Communication link for battery management system |
7 | Line circuit breaker for inverter |
8 | KOSTAL Smart Energy Meter (Modbus RTU) at the grid connection point |
9 | Main fuse for building |
10 | Procurement and feed meter or smart meter (not in all countries) |
11 | Public grid |
12 | Line circuit breaker for energy consumers |
13 | Energy consumers |
14 | Communication link for ENECTOR wallbox |
15 | Line circuit breaker for ENECTOR wallbox |
16 | ENECTOR wallbox |
Product upgrades
Product upgrades can be activated using activation codes. This requires PLENTICOINs.
The PLENTICOIN is a single-purpose voucher for product upgrades. The PLENTICOIN can be redeemed in the online KOSTAL Solar shop against the required activation code (e.g. battery upgrade). The PLENTICOIN is purchased through specialist wholesalers.
The following product upgrades are available and can be obtained in the KOSTAL Solar Webshop using PLENTICOIN:
The product upgrades can then be activated using the KOSTAL Solar App, the inverter display or the inverter Webserver by going to Additional options and entering the activation code.
- Battery upgrade
Allows a battery to be connected to the DC input for the battery. - Power upgrade
Increases the inverter’s basic power by up to two levels
Power classes
The inverter is available in two sizes, S and M, with a basic power level of 3.0 to 7 kW.
The basic power level can be increased by two levels using an optional product upgrade (power upgrade) to make system planning as flexible as possible.
The power upgrade can also be done later, without having to replace the inverter.
The power activated in the inverter can be marked on the type plate. The activated power is also shown in the inverter's parameter report, available from the Webserver, and on the inverter's display.
Size | Basic power | Level 1 | Level 2 |
---|---|---|---|
PLENTICORE MP S G3 | 3.0 | 3.6 / 4.0 | --- |
PLENTICORE MP M G3 | 4.6 / 5.0 | 6.0 | 7.0 |
PLENTICORE MP S G3: Only one PLENTICOIN in total is required for the 3.6 and 4.0 power upgrade.
PLENTICORE MP M G3: The 4.6 and 5.0 basic power level depends on the country of use and is set via the set of country parameters.
You can find more information in the technical data.